An on-grid inverter’s main job is to convert DC power generated from the PV array into usable AC power. Hybrid inverters go a step further and work with batteries to store excess power as well. In the developing world, hybrid inverters are more of a necessity to compensate for weak or intermittent grids or a lack of grid electricity altogether.
Pure sine wave inverter
Built-in PWM solar charge controller
Selectable input voltage range and frequency according to city power in your country
Charging current is settable according to your battery type
Configurable AC/Solar input priority via LCD setting
Compatible to mains voltage or generator power
Auto restart while AC is recovering
Overload and short circuit protection
Smart battery charger design for optimized battery performance
Cold start function
Model NO.
|
TTN-PS 1K
|
TTN-PS 3K
|
TTN-PS 5K
|
|
Rated Power
|
1000VA/800W
|
3000VA/2400W
|
5000VA/4000W
|
|
INPUT
|
Phase&waveform
|
230 VAC
|
||
Voltage selectable range
(for Personal Computer) |
170~280 VAC
|
|||
Voltage selectable range
(for home appliance) |
90~280 VAC
|
|||
Frequency range
|
50Hz/60Hz (Auto sensing)
|
|||
OUTPUT
|
AC voltage Regulation
(Batt.Mode) |
230V AC ± 5%
|
||
Surge Power
|
2000VA
|
6000VA
|
10000VA
|
|
Efficiency (Peak)
|
90%
|
93%
|
||
Transfer time
|
10ms (for personal computer),20ms (for home appliance)
|
|||
Wave form
|
Pure sine wave
|
|||
Battery& AC Charger
|
Battery voltage
|
12VDC
|
24VDC
|
48VDC
|
Floating charge Voltage
|
13.5VDC
|
27VDC
|
54VDC
|
|
Overcharge Protection
|
15VDC
|
30VDC
|
60VDC
|
|
Maximum Charge Current
|
10A or 20A
|
20A or30A
|
10A/20A/30A/40A/50A/60A
|
|
PV Input
|
Charge current
|
50A
|
||
MPPT Range @
Operating Voltage (VDC) |
50VDC
|
60VDC
|
105VDC
|
|
Standy powr consumption
|
1W
|
2W
|
2W
|
|
Physical
|
Dimension, D×W×H (mm)
|
305x300x110
|
305x272x100
|
413x295x120
|
Net Weight (Kgs)
|
4.5
|
6.9
|
9.8
|
|
Environmental
|
Humidity
|
5%~95% Relative Humidity (Non-condensing)
|
||
Operation Temperature
|
0℃~55℃
|
|||
Storage Temperature
|
-15℃~60℃
|